Troubleshooting an uncooperative hearth during chilly weather often traces back to ignition failure, corroded thermopiles, or worn millivolt valves. Keeping a Heatilator Caliber Propane Fireplace Series running reliably requires exact component matching, especially when dealing with liquid propane setups that demand precise gas pressure and proper burner alignment. A weak pilot flame or intermittent burner dropout usually signals that it is time to inspect the pilot tube, thermocouple, and wiring harness. Homeowners maintaining these heating appliances often compare compatible components alongside broader gas fireplace parts and replacement components to locate the exact match for their standing pilot or intermittent pilot ignition systems.
Sourcing the correct replacement hardware prevents frustrating trial and error, as liquid propane assemblies differ fundamentally from natural gas setups in orifice size and operating pressure. Whether your unit utilizes a traditional standing pilot or an electronic IPI module, verifying the model number, lead length, and valve type ensures your liquid propane fireplace continues to deliver steady supplemental warmth. Examining verified product specifications and valve cross-reference numbers helps you secure durable, properly fitting parts without unnecessary installation delays.
Pros
- Direct part-number replacement for legacy Heatilator 25732 and HHT 4021-729
- Factory-configured specifically for liquid propane (LP) installations
- Restores pilot ignition and flame sensing on compatible Quadra-Fire and Heatilator appliances
- Durable metallic build matches original appliance hardware
Cons
- Designed strictly for propane and cannot be used with natural gas installations
- Requires cross-referencing appliance parts manuals since specific model compatibility is not itemized in the base data
- Gas line and pilot replacement typically requires professional technician installation to ensure safe, leak-free operation
The Heatilator 25732 (also identified under Hearth and Home Technologies part number 4021-729) is a dedicated replacement pilot assembly built specifically for liquid propane (LP) gas fireplaces. Designed for legacy models from Heatilator and Quadra-Fire, this component is targeted at homeowners, rental property managers, and service technicians who need to restore dependable ignition and flame stability to an existing propane fireplace without replacing the complete burner system.
Pilot assemblies serve as the ignition core for gas hearth appliances, providing the constant or intermittent flame necessary to heat safety sensors and ignite the main burner. When a pilot assembly corrodes, clogs, or suffers structural fatigue over years of heating cycles, the fireplace may struggle to light, fail to hold a flame, or frequently shut down. Because this component is built specifically for propane use, it features the appropriate orifice and flow characteristics required for higher-pressure LP systems.
The assembly features a standard silver metallic construction designed to withstand the harsh, continuous heat environment around the fireplace burner tray. Its physical configuration reflects original equipment specifications from Hearth and Home Technologies, allowing it to mount into the original bracket orientation and align properly with the main burner porting on supported appliances.
Working with gas components requires strict adherence to safety and manufacturer procedures. Replacing a pilot assembly involves disconnecting gas pilot tubing, handling ignition wiring, and reseating safety sensors. Anyone installing this part must ensure that all gas connections are shut off prior to service and thoroughly tested for leaks with an approved solution before firing the unit. Because gas work carries fire and carbon monoxide considerations, hiring a licensed gas professional is widely recommended.
The primary limitation of this part is its strict fuel specificity and narrow compatibility window. This assembly is engineered solely for propane systems and will not function properly or safely on natural gas lines without dangerous combustion issues. Furthermore, because specific model names are not listed in the raw data, buyers must check their existing fireplace rating plate or owners manual to confirm that part 25732 or 4021-729 is the exact recommended replacement.
For owners of compatible Heatilator and Quadra-Fire propane fireplaces experiencing erratic pilot performance, the 25732 / 4021-729 pilot assembly provides a direct, cost-effective repair solution. Verifying your appliance part number and utilizing qualified gas service ensures a safe restoration of your fireplace heating functionality.
Compatibility for this pilot assembly relies on matching specific manufacturer part numbers rather than general fireplace dimensions. The assembly directly replaces obsolete Heatilator part number 25732 and corresponds to Hearth and Home Technologies (HHT) part number 4021-729.
This component is engineered for select legacy gas appliances manufactured under the Heatilator and Quadra-Fire brands. Buyers should locate the metal rating plate typically found inside the lower control compartment of the fireplace to confirm the appliance model number, fuel type, and original part specifications prior to ordering.
This pilot assembly is configured exclusively for liquid propane (LP) fuel. Propane operates under different manifold pressures and requires different orifice sizing than natural gas, meaning this component must never be installed on a natural gas appliance.
Any service involving gas supply lines, pilot tubing, and ignition components should comply with applicable local codes and manufacturer instructions. Professional installation by a certified gas technician or hearth specialist is strongly advised to verify proper pilot flame pattern, secure connections, and leak-free operation.
Pros
- Includes both the thermocouple and thermopile pre-mounted in one assembly
- Long lead lengths (36 inches for thermopile, 24 inches for others) simplify firebox routing
- Direct replacement match for common HHT numbers 4021-737 and 485-511A
- Backed by a 1-year manufacturer replacement warranty
Cons
- Configured strictly for liquid propane (LP) fireplaces and will not work with natural gas
- Requires exact cross-referencing of your fireplace model number to verify fit
- Working with gas lines and tight valve connections may require professional service if you lack installation experience
The Criditpid 4021-737 Propane Gas Pilot Assembly is a direct-replacement service component engineered specifically for liquid propane (LP) fireplaces manufactured under Hearth and Home Technologies (HHT) brands. If your existing pilot flame fails to stay lit, drops out intermittently, or produces insufficient electrical output to open the main burner valve, this assembly offers a targeted fix. It is designed for homeowners, property managers, and technicians servicing select Heatilator, Heat N Glo, and Quadra-Fire propane fireplace units.
Functionally, this kit bundles every critical part required for standing or intermittent pilot ignition in a single drop-in package. It incorporates a pilot burner head, a 36-inch thermopile, a 24-inch thermocouple, a 24-inch aluminum pilot line, and a 24-inch ceramic ignitor lead. When functioning properly, the thermocouple maintains the pilot safety circuit, while the 750-millivolt generator (thermopile) generates the electrical current required to operate the primary wall switch, remote receiver, and gas control valve.
Build quality focuses on heat resistance and long-term durability in high-temperature hearth environments. The assembly uses standard mounting brackets and corrosion-resistant metal fittings that match the original factory layout, which helps maintain the exact flame angle over the sensing probes. Replacing the entire assembly at once prevents common troubleshooting headaches, as piecemeal fixes often leave older, degraded sensors in place beside new parts.
Installation is straightforward for experienced DIYers or gas professionals, primarily because the wiring and line dimensions are pre-sized to factory standards. The 36-inch thermopile gives you ample slack to navigate through heat shields and floor knockouts to reach the valve beneath the burner pan. However, because this component connects directly to the propane gas supply and regulates combustion safety, you must ensure leak-free connections and follow all fireplace manufacturer instructions during replacement.
A critical limitation of this part is fuel compatibility. It is calibrated strictly for liquid propane (LP) systems and must not be used on natural gas setups due to differences in orifice sizing and gas pressure. Buyers must also cross-reference their exact model designation against the verified compatibility list, as similar model series often utilize different pilot configurations across manufacturing years.
For owners of compatible Heat N Glo, Heatilator, or Quadra-Fire fireplaces experiencing stubborn ignition failures or worn millivolt sensors, this Criditpid replacement assembly provides an economical, practical solution. Backed by a 1-year warranty, it supplies all the necessary parts in one package to restore dependable heat and ambiance to your propane hearth.
This pilot assembly directly replaces OEM part number 4021-737 and older part number 485-511A. Always locate the data rating plate on your fireplace chassis to confirm your exact model before ordering.
Compatible Heat N Glo models include: AT-Grand-B, AT-Grand-C, AT-Grand-D, AT-Supreme-B, CFX-Grand-B, CFX-IN-B, FB-Grand, 6000TRB, 6000TRI, 6000TRI-SP, 6000TR-OAK, 7000TR-NF, 7000TV-NF, 7000XLS-NF, BE-41, BE-41B, SL-350TRS, and SL-350TV.
Compatible Heatilator models include: NB3630, NB3933, NB4236, NB4842, ND3630, ND3630L, ND3630M, ND3933, ND3933L, ND3933M, ND4236, ND4236L, ND4236M, ND4842, ND4842L, and ND4842M.
Compatible Quadra-Fire models include: QV32, QV32-A, QV36, QV36-A, QV36D, QV36D-A, QV36DB, QV36DB-A, QVI-30FB, QV-Pier, and QV-ST.
This assembly is exclusively designed for liquid propane (LP) fuel supplies. Do not attempt to install or modify this assembly for use with natural gas, as incorrect orifice sizing can create dangerous combustion conditions.
The package provides a 36-inch thermopile lead alongside 24-inch thermocouple, ignitor, and pilot line lengths. Ensure proper routing away from sharp metal edges and out of direct contact with the main burner flame.
Always shut off the gas supply and disconnect electrical power before servicing any fireplace component. Test all disturbed gas connections with an approved non-corrosive leak detection solution prior to relighting the pilot.
Pros
- Exact-fit replacement for part numbers 4021-423 and 4021-026 across major Hearth and Home Technologies brands
- Includes pilot tubing, wiring leads, and mounting bracket in a single pre-assembled package
- Dedicated propane configuration provides proper flame sensing and main burner ignition on LP setups
- Broad compatibility covering multiple popular Heat-N-Glo and Heatilator direct-vent and insert models
Cons
- Compatible only with Intermittent Pilot Ignition (IPI) systems and will not work on standing pilot, DSI, or HSI units
- Configured strictly for propane gas and cannot be used in natural gas fireplaces
- Requires careful installation to avoid sharp bends or kinks in the aluminum pilot tube
The ETERMETA 4021-423 Pilot Assembly is a specialized replacement component engineered for select propane-fueled gas fireplaces manufactured under Hearth and Home Technologies brands, including Heat-N-Glo, Heatilator, Majestic, and Quadra-Fire. This part directly targets homeowners, rental property managers, and fireplace repairers who are experiencing pilot light failures, non-responsive ignition sequences, or flame-sensing dropouts on units equipped with an electronic Intermittent Pilot Ignition (IPI) system.
Functioning as the ignition and safety-monitoring center of the fireplace, this assembly delivers the pilot flame that subsequently lights the main burner. Because it is configured specifically for propane (LP) gas, the internal orifice sizing and flame pattern are tailored to propane delivery pressures. The pre-attached electrode leads communicate with the fireplace control module to generate the spark and sense the pilot flame, ensuring the main gas valve only opens when a stable flame is verified.
Construction quality centers on functional durability and straightforward replacement. The kit includes a pre-formed mounting bracket, the pilot hood, ignition and sensing wires, and an aluminum pilot tube. Having the leads pre-attached prevents the need to splice or alter wiring in the tight lower compartment of the fireplace, helping maintain solid electrical continuity back to the IPI ignition module.
Installation requires closing the main gas supply line and turning off electrical power to the fireplace before handling components. The assembly mounts into the existing burner bracket location. During setup, avoiding sharp bends or pinches in the pilot tubing is critical, as restricted gas flow can cause weak pilot flames and ignition lockouts. Anyone uncomfortable working with gas lines and electrical ignition connections should have a qualified technician complete the install and perform a standard leak test.
Buyers should keep clear limitations in mind before ordering. This assembly is designed strictly for electronic IPI systems; it does not fit traditional standing pilot (continuous millivolt), direct spark ignition (DSI), or hot surface ignition (HSI) fireplaces. Additionally, it is calibrated exclusively for liquid propane and will not operate properly on natural gas systems without separate, proper conversion components.
For owners of compatible Heat-N-Glo, Heatilator, Majestic, or Quadra-Fire propane fireplaces experiencing intermittent sparking or pilot outage errors, the ETERMETA 4021-423 provides a practical and cost-effective direct replacement. Verifying your fireplace model number, existing part tag, and propane fuel configuration ensures this kit will restore dependable heating performance.
Direct replacement for OEM part numbers: HHT 4021-423, SRV4021-423, and old part number 4021-026.
Compatible Heat-N-Glo models: 6000BE-IPI, 6000TRI-IPI, 6000TR-OAK-IPI, 6000TRXI-IPI, 6000TV-OAK-IPI, 6000PLUS, 8000CF-OAK-IPI, 8000TRD-IPI, 8000TR-OAK-IPI, 8000TVD-IPI, 8000TV-OAK-IPI, SOULSTICE, SL-550TRS-IPI-D, and SL-750TRS-IPI-D.
Compatible Heatilator models: GCDC60i, GCDC60Li, GCDC80i, GCDC80Li, NB4236IPLUS, NB4236ILPLUS, ND3630I, ND3630IL, ND3630MI, ND3933I, ND3933IL, ND3933MI, ND4236I, ND4236IL, ND4236MI, ND4842I, and ND4842IL.
Compatible Quadra-Fire models: QV36A-FB (Expression), as well as select Majestic units calling for part 4021-423.
Always shut off the gas supply and disconnect electrical power or remove battery backup packs before servicing the fireplace.
Route the aluminum pilot tube gently without sharp bends, kinks, or flat spots that could restrict propane flow or compromise line integrity.
This component is restricted strictly to Intermittent Pilot Ignition (IPI) systems using liquid propane (LP) fuel; do not install it on natural gas or standing pilot appliances.
Always verify all gas connections with a gas leak detection fluid prior to test-firing the fireplace, or hire a qualified gas professional if unfamiliar with fireplace repairs.
Pros
- Matches OEM part number 4021-733 for Heatilator and Heat-n-Glo gas fireplaces
- Configured specifically with the proper orifice for liquid propane (LP) fuel
- Sturdy metal construction holds up against high firebox ambient temperatures
- Cost-effective solution for resolving ignition and pilot outage issues
Cons
- Strictly configured for propane (LP) systems and cannot be used on natural gas setups
- Appliance manual must be cross-checked to confirm 4021-733 matches your specific model and revision
- Gas component installation requires strict adherence to safety codes and often warrants a qualified technician
The Heatilator and Heat-n-Glo 4021-733 Propane Gas Pilot Assembly is a specialized replacement part designed for compatible liquid propane (LP) fireplaces. It is ideal for existing fireplace owners, rental property managers, and repair technicians seeking to resolve pilot lighting issues, ignition failures, or worn flame components in supported Heatilator and Heat-n-Glo hearth units.
Reliable pilot operation is essential for the safe and consistent functioning of any standing or intermittent gas fireplace. Over time, pilot orifices can corrode, carbon up, or suffer physical wear, resulting in weak pilot flames that drop out or fail to heat the safety sensors properly. Replacing the worn assembly with this dedicated LP part helps restore the proper flame pattern and fuel delivery necessary to keep the pilot lit and ignite the main burner reliably.
Built from durable silver-tone metal components, this pilot assembly is manufactured to withstand the typical heat cycles found inside a gas fireplace firebox. Measuring approximately 8 x 2 x 5 inches overall, the unit is sized to sit neatly beside the main burner tray, using factory-standard bracket spacing for straightforward mechanical mounting.
Because this part is calibrated specifically for liquid propane fuel, proper installation requires verifying that your fireplace is set up for LP and not natural gas. Working with gas lines, fittings, and ignition hardware involves inherent safety considerations. Homeowners should verify that all gas supplies are fully shut off prior to maintenance, follow all manufacturer guidance, and hire a licensed gas professional if unfamiliar with gas line connections.
A critical consideration before ordering is verifying exact part number compatibility. Fireplace models from Heatilator and Heat-n-Glo can utilize different pilot brackets, ignition leads, and valve configurations depending on the production year and fuel setup. Checking your fireplace rating plate or owner's manual for part number 4021-733 is necessary to ensure an accurate fit.
For owners of compatible Heatilator and Heat-n-Glo propane fireplaces experiencing pilot dropouts or ignition failure, this replacement pilot assembly offers a dependable, targeted solution that restores original hearth operation without the need for costly complete system replacements.
Compatibility for this component is defined strictly by the manufacturer part number 4021-733. It is designed for use in select Heatilator and Heat-n-Glo gas fireplaces configured for liquid propane (LP).
Do not assume fitment based on appearance or general brand name alone, as bracket shapes and sensor configurations change across model revisions. Always consult the rating plate or the replacement parts list in your fireplace manual to ensure part 4021-733 is specified.
This pilot assembly is designated exclusively for liquid propane (LP) fuel systems. It should never be connected to a natural gas line, as orifice sizing and pressure requirements differ significantly between fuel types.
All gas connections, pilot tubing, and ignition components must be checked for leaks using an approved leak-detection solution before relighting. Local mechanical codes and safety best practices recommend utilizing a qualified gas technician for the installation of safety pilot hardware.
Pros
- Direct replacement part for part number 060-523 across multiple direct-vent gas fireplace brands
- Calibrated for variable liquid propane (LP) fuel systems with manual flame modulation
- Millivolt design operates independently of household line voltage during power outages
- Significantly more accessible alternative to expensive original manufacturer replacement assemblies
Cons
- Configured strictly for liquid propane and cannot be connected to natural gas lines
- Gas line disconnection, component installation, and safety leak testing require careful mechanical skill or professional service
- Generic aftermarket packaging does not include replacement mounting brackets, gaskets, or printed instructions
The 060-523 replacement gas valve is a variable millivolt valve specifically configured for liquid propane (LP) direct-vent fireplaces. Built to replace OEM part number 060-523, this component caters directly to existing owners of Heat N Glo, Heatilator, and Quadra-Fire direct-vent units who are experiencing weak burner output, pilot issues, or valve failure. For homeowners and service professionals managing aging gas appliances, sourcing a reliable replacement valve is essential to restoring safe, adjustable heat output.
In terms of functionality, this valve operates within standard millivolt control systems, using the voltage generated by a standing pilot thermopile to actuate the gas flow. Because millivolt systems do not depend on external household electricity to open the main gas valve, it ensures your direct-vent fireplace can deliver reliable heat even during winter power outages. The variable control knob enables flame modulation, letting you dial the propane flame height up or down depending on your current room heating needs.
The build quality reflects precision aftermarket engineering tailored for durability in high-heat appliance enclosures. The metal valve body includes the standard input and output gas fittings, pilot tube connection, and electrical terminal blocks needed to integrate seamlessly with existing millivolt wall switches or thermopiles. While marketed by a generic brand, the component is manufactured to match the form factor and operational thresholds of the original factory part it replaces.
Installation demands caution and precise alignment with your existing direct-vent gas setup. Working with propane lines requires shutting off the gas supply, disconnecting the thermocouple and pilot lines, and threading the valve correctly into the burner manifold. Given the safety risks associated with pressurized combustible fuel, DIYers should possess mechanical experience, and most homeowners will benefit from hiring a licensed gas technician to complete the swap and perform mandatory soapy water or electronic leak checks.
Before purchasing, verification of your exact fireplace model and fuel type is critical. This valve is strictly intended for liquid propane (LP) configurations and is incompatible with natural gas supply lines. While the compatibility list is expansive-spanning models like the 6000TRB, 8000TVC, and SL-550TR-C-always cross-check your fireplace owner manual or existing valve label to confirm that part 060-523 is the specified millivolt LP valve for your appliance.
Overall, the 060-523 variable LP valve offers a practical, budget-conscious repair path to breathe new life into an existing direct-vent fireplace. If your Heat N Glo, Heatilator, or Quadra-Fire fireplace suffers from gas delivery failures or an unresponsive control knob, this direct-fit replacement valve provides a dependable way to restore variable propane warmth to your living space.
This replacement valve replaces part number 060-523 and fits a broad range of direct-vent gas appliances from Heat N Glo, Heatilator, and Quadra-Fire. Documented model fits include the Quadra-Fire QV32, QV36, and QVi series inserts (QVi25, QVi30, QVi35), alongside Heat N Glo R-series models (R-3500, R-4500, R-5500, R-6500).
It also supports extensive flagship Heat N Glo direct-vent models, including the 6000 series (6000BE, 6000CAMP, 6000DVTFL, 6000GDVFL, 6000TRB, 6000TVB, 6000XLS), 7000 series, and 8000 series (8000DVTFL, 8000GDVFL, 8000TR, 8000TVC), as well as SL series models like the SL-350TRS and SL-550TR. Always confirm your model number on the rating plate inside your fireplace control compartment before ordering.
This valve is calibrated specifically for liquid propane (LP) gas pressure and flow characteristics. Do not attempt to install or connect this component to a natural gas line, as natural gas operates under significantly different delivery pressures and manifold requirements.
Gas appliance repairs carry inherent risks of gas leaks, carbon monoxide exposure, and fire. All installations should include fresh thread sealant rated for LP gas, strict adherence to manufacturer torquing specifications, and thorough leak testing prior to lighting the standing pilot. If you are not fully confident in handling gas fittings, engage a qualified gas technician.
Pros
- Includes both thermocouple and thermopile to restore both pilot hold and main burner control.
- Provides an economical alternative to purchasing costly individual OEM components.
- Pre-attached bracket and electrode simplify replacement inside tight firebox valve compartments.
- Broad compatibility across major vintage Heatilator, Heat-N-Glo, and Quadra-Fire propane models.
Cons
- Strictly limited to liquid propane (LP) systems with no natural gas orifice included.
- Incompatible with electronic Direct Spark Ignition (DSI) systems or intermittent pilot modules.
- Requires cross-referencing fireplace serial numbers on certain models like CD4236 and GDCL60.
The Criditpid 4021-733 LP Pilot Assembly is an aftermarket replacement cluster designed specifically for standing-pilot liquid propane fireplaces made by Hearth & Home Technologies brands, including Heatilator, Heat-N-Glo, and Quadra-Fire. When an older gas fireplace struggles to keep its pilot light lit or fails to signal the main gas valve to open, the problem usually stems from a degraded thermocouple, an exhausted thermopile, or a fouled pilot hood. This full assembly suits homeowners and maintenance personnel who prefer swapping out the entire ignition assembly at once rather than diagnosing and replacing fragile individual wires and sensors piecemeal.
Functionally, this unit restores standard millivolt standing pilot operations. It houses a built-in thermocouple that generates the necessary electrical current to hold the pilot safety valve open once heated by the pilot flame. Alongside it sits a multi-junction thermopile generator, responsible for producing the higher millivolt output required to operate the main burner via a wall switch, thermostat, or remote control receiver. The integrated sparker electrode provides the spark needed to light the pilot gas flowing through the pilot tube, while the directed hood ensures both sensors are properly engulfed in the propane flame.
In terms of construction, the assembly comes fixed to a rigid mounting bracket that positions each element at the proper angle and spacing relative to the pilot orifice. The copper thermocouple line and insulated thermopile lead wires provide enough length and flexibility to navigate through the firebox floor down to the gas valve manifold beneath. Because pilot assemblies operate continuously within high-heat combustion zones, replacing the full bracket and sensor group together ensures renewed corrosion resistance and consistent flame sensing.
Replacing a pilot cluster requires careful attention to gas line seals and fragile sensor wiring. The installation involves shutting off the gas supply, disconnecting the aluminum pilot supply tube, unscrewing the thermocouple and thermopile leads from the valve, unfastening the old bracket, and threading the new components into position. Because this is a propane-specific part, using the proper flare fittings and testing all joints with an approved gas leak detection solution before relighting the appliance is essential.
The primary operational limitation of this product is its narrow fuel and ignition specificity. It is built strictly for liquid propane (LP) installations and cannot be installed on natural gas lines without causing dangerous combustion imbalances and sooting. Furthermore, it works only on manual standing pilot systems; it is completely incompatible with electronic intermittent pilot or Direct Spark Ignition (DSI) systems. Prospective buyers must also verify their fireplace model and serial numbers, as models such as the Heatilator CD4236R or GDCL60L require this assembly only on builds prior to specific serial number cutoffs.
For owners of compatible Heatilator, Heat-N-Glo, or Quadra-Fire propane fireplaces experiencing erratic pilot behavior, weak thermopile voltage, or failed ignition, the Criditpid 4021-733 offers a direct, functional remedy. By combining the pilot hood, sparker, thermocouple, and thermopile onto a single factory-aligned bracket, it provides a cost-effective path toward restoring safe, dependable supplemental heat for the winter season.
This pilot assembly serves as a direct cross-reference replacement for OEM part numbers 4021-733, 25661, SRV4021-733, 25175, and SRV25175 across several major hearth brands. It is engineered for traditional standing-pilot configurations and will not function with electronic spark ignition systems.
For Heatilator fireplaces, compatible models include the GNDC30, GNDC33, GNDC36, GNRC36, GBiS36, GBIS36L, GCBC36, GCBC42, GCBC60, GCBC80, GCDC36, GCDC42, GCDC60, GCDC80, GDCH36, GDCR36, and associated L-designated propane models. Note that CD4236R, CD4236LR, CD4842R, and CD4842LR models require verification that the unit was built prior to serial number GA1563745, while GDCL60 and GDCL60L units must precede serial number GA1549727.
Compatible Heat-N-Glo propane units include the 6000XL, 6000XLT, 8000DVTFL, 8000TR, Bayfyre-TRS, BAY-GDV-95, SL-36GDV, SL-36S, SL-42, SL-42DVT, and SL-3000. It also matches Quadra-Fire appliances calling for part number 4021-733 or 25661. Always confirm your model number, serial number tag, and fuel type on the fireplace rating plate before ordering.
This pilot assembly is configured solely for liquid propane (LP) gas. Propane operates under different supply pressures and requires different orifice sizing than natural gas. Attempting to install this pilot assembly on a natural gas fireplace can result in improper combustion, heavy soot accumulation, and hazardous operating conditions.
Any work involving fireplace gas lines, pilot tubes, and valve connections should be performed with the gas supply turned completely off. Once installation is complete, test all gas line fittings with an approved non-corrosive gas leak detection fluid before attempting ignition.
If you are unfamiliar with gas line connections, millivolt wiring, or pilot safety testing, consider having the component installed and checked by a licensed gas fitter or certified fireplace technician to ensure full compliance with local building codes and manufacturer safety requirements.
Pros
- Direct replacement fit for HHT part numbers 4021-423 and 4021-026
- Pre-assembled package includes ignitor wire, electrode, pilot hood, and mounting bracket
- Restores reliable spark and ignition for intermittent pilot ignition (IPI) setups
- Budget-friendly repair option compared to replacing complete burner assemblies
Cons
- Configured strictly for propane (LP) and cannot be used on natural gas setups
- Incompatible with standing pilot, direct spark ignition (DSI), or hot surface ignition (HSI) systems
- Requires shutting off gas lines and careful handling to avoid bending or kinking the copper tubing
The Hipoilk 4021-423 Propane IPI Pilot Assembly is a specialized fireplace replacement component engineered for owners of Heatilator, Heat N Glo, and QuadraFire gas appliances. When an intermittent pilot ignition system fails to light, produces a weak spark, or struggles to sense flame, replacing the entire pilot cluster is frequently the most practical repair. This kit serves as a direct alternative to factory Hearth & Home Technologies part numbers 4021-423 and 4021-026, targeting homeowners and repair technicians seeking to resolve start-up troubles without purchasing expensive OEM burner kits.
Functionally, this pilot assembly is responsible for delivering the initial propane flame that lights the main fireplace burner. Because it is designed for intermittent pilot ignition (IPI) systems, the unit ignites electronically on demand rather than burning a continuous standing flame. The package includes the pilot hood, fuel tubing, spark electrode, pre-attached ignitor wiring, and the bracket that seats immediately adjacent to the main burner. Replacing an aged or sooted assembly helps restore clean fuel flow and consistent spark transfer, cutting down on delayed ignition or repeated system lockouts.
Component construction focuses on durability under standard fireplace operating temperatures. The assembly incorporates quality metal housing, ceramic insulation on the electrode, and standard copper pilot line tubing to resist prolonged thermal fatigue. While built for regular hearth duty, the manufacturer explicitly cautions against bending the copper tubes excessively during placement, as sharp kinks can restrict propane flow or compromise the gas seal.
Installation requires moderate mechanical and gas safety awareness. Before beginning any work, you must fully disconnect the fireplace gas supply and shut off electrical power to the control module. Swapping the pilot entails dismounting the old bracket from the burner area, threading the new ignitor wire to the control module, securing the gas tube fitting, and mounting the bracket securely. Because improper gas connections present safety hazards, anyone unfamiliar with flared gas fittings or leak testing should consult a qualified gas technician.
The most important limitation of this product is its strict fuel and ignition specificity. This assembly is built exclusively for propane (LP) systems and will not function properly or safely with natural gas without proper factory orifices. Furthermore, it is engineered only for IPI systems and cannot be installed in fireplaces that utilize standing pilot valves, direct spark ignition (DSI), or hot surface ignition (HSI) controls.
For owners of compatible Heatilator models like the ND4236I or ND3933I, and Heat N Glo units like the 6000TR or SL-550TRS, this Hipoilk pilot assembly is a sensible, cost-effective replacement. As long as you verify your fireplace model number, fuel type, and ignition system before ordering, this all-in-one kit offers a dependable path to getting your fireplace ambiance and heat running smoothly again.
This pilot assembly replaces OEM part numbers 4021-423 and 4021-026 across select Hearth & Home Technologies (HHT) brand families, including Heatilator, Heat N Glo, and QuadraFire.
Documented model compatibility includes the Heatilator ND4236I and ND3933I, as well as the Heat N Glo 6000TR and SL-550TRS gas fireplaces running intermittent pilot systems.
Do not use this assembly on natural gas fireplaces, standing pilot setups, direct spark systems (DSI), or hot surface ignition (HSI) appliances. Always check the model rating plate inside your fireplace control cavity to confirm part compatibility before purchasing.
Always disconnect the main gas supply and unplug the electronic ignition control module before attempting to replace fireplace pilot components.
Exercise care when routing the copper pilot feed line. Avoid tight radiuses, excessive bending, or kinking the tube, as copper can work-harden or crimp, restricting propane delivery to the pilot orifice.
After completing installation, always perform a thorough soap-and-water bubble test on all gas connections to verify that no fuel leaks exist before lighting the fireplace.
Pros
- Direct replacement compatibility with Robertshaw 446-511 and part numbers 34820 and 72956
- 27-inch overall length provides ample slack for routing in most direct-vent fireplace lower cavities
- Constructed with standard copper lead for effective heat transfer and signal conductivity
- Fine-thread terminal nut fits Robertshaw and specific SIT 820 NOVA valve connections
Cons
- Only fits fine-thread valve ports and will not work on gas valves requiring coarse threads
- Does not replace thermopiles or pilot generator assemblies that produce higher millivolt outputs for wall switches
- Requires careful physical comparison with the existing thermocouple before ordering to verify thread size and lead length
The Fixitshop 27-Inch Direct Vent Fireplace Thermocouple is a targeted replacement part designed for gas hearth appliances experiencing pilot retention trouble. If a direct-vent gas fireplace pilot lights manually but immediately goes out the moment the control knob is released, a worn or faulty thermocouple is often the underlying cause. This component serves homeowners, rental property managers, and DIY repairers looking for a direct-fit fix for worn safety sensors on compatible Heatilator, Heat & Glo, and similar gas fireplace systems.
Functionally, this thermocouple acts as an analog safety sensor within the pilot assembly. When engulfed in the standing pilot flame, the copper probe tip generates a small millivolt charge that signals the internal magnet of the gas control valve to remain open. Product specifications confirm that this unit directly replaces Robertshaw part 446-511, along with cross-reference part numbers 34820 and 72956. It is specifically designed to mate with Robertshaw valves as well as select SIT 820 NOVA gas valves that use fine thread connectors.
In terms of materials and construction, the unit features a copper line and sensor head measuring 27 inches in length, weighing just under 0.1 pounds. The copper tubing provides both thermal conductivity and enough flexibility to be gently guided through burner base grommets or tight valve access openings without crimping. The terminal end is fitted with a fine-thread nut designed to thread securely into the back of the compatible control valve head.
Installation involves routing the sensor end into the pilot burner bracket next to the pilot hood and tightening the threaded connection at the valve port. Because the copper line is 27 inches long, it provides enough reach for most standard direct-vent fireplace configurations where the valve sits beneath the firebox floor. Installers must take care not to over-tighten the fine brass threads at the valve or bend the copper line at sharp 90-degree angles, as crushing the internal lead can interrupt the electrical signal.
The primary limitation of this part is connection specificity. Gas fireplaces utilize both fine-thread and coarse-thread fittings, and this unit is strictly built for fine-thread Robertshaw and select SIT 820 NOVA connections. Furthermore, a thermocouple should not be confused with a two-lead thermopile (pilot generator); this single-lead thermocouple solely monitors the pilot to keep the valve open, rather than powering remote wall switches or blowers. Buyers should inspect their current pilot assembly and valve specifications prior to purchasing.
For owners of compatible Heatilator, Heat & Glo, or Robertshaw-equipped direct-vent fireplaces facing pilot outage issues, this Fixitshop replacement offers a practical, low-cost repair part. When verified against your appliance manual for thread type and lead length, it delivers the exact physical and electrical interface required to restore dependable fireplace ignition.
Compatibility for this thermocouple depends entirely on thread type and valve model. This part is identified as a replacement for Robertshaw part number 446-511, as well as interchangeable part numbers 34820 and 72956 commonly found in Heatilator and Heat & Glo direct-vent gas fireplaces.
The terminal end features a fine-thread connection designed to seat into Robertshaw control valves and select SIT 820 NOVA series gas valves. It will not fit valves engineered for coarse-threaded thermocouple nuts or quick-drop coaxial fittings. Always verify the part number in your fireplace owner manual or check the thread pitch on your existing failed sensor before ordering.
When servicing any gas fireplace component, the gas supply to the appliance must be shut off completely before beginning work. Ensure the fireplace and all pilot components are completely cool to the touch.
Take care when routing the 27-inch copper tubing from the pilot bracket to the valve compartment. Avoid sharp kinks, tight bends, or pinching the copper line against sharp sheet metal edges. Thread the connector nut into the valve port by hand first to avoid cross-threading, then snug it gently with a small wrench without over-torquing the fine threads. If you are uncomfortable working around gas lines or burner assemblies, consult a qualified gas service professional.
Frequently Asked Questions
How do I know if my Heatilator Caliber Propane Fireplace Series uses a standing pilot or an IPI ignition system?
Check the lower control compartment beneath the fireplace burner for a continuous flame or an electronic control module. Standing pilot setups feature an adjustable gas knob on a millivolt valve and maintain a constant flame. Intermittent pilot ignition (IPI) units use an electronic spark module to light the pilot only when calling for heat. Assemblies like part 4021-423 fit IPI units exclusively and cannot replace standing pilot assemblies.
Can I use a natural gas pilot assembly on a propane Heatilator Caliber Propane Fireplace Series?
No, liquid propane and natural gas pilot assemblies cannot be interchanged. Propane operates under higher manifold pressure and requires a much smaller orifice opening than natural gas. Installing a natural gas pilot on a propane line causes excessive fuel flow, improper combustion, soot buildup, and safety risks. Always confirm that replacement pilot assemblies, like part 4021-737 or 4021-733, explicitly list propane compatibility.
What causes the pilot flame on a Heatilator Caliber Propane Fireplace Series to shut off when releasing the knob?
A weak or malfunctioning thermocouple is the primary cause of a pilot flame extinguishing once the control knob is released. The thermocouple generates millivoltage from the pilot flame heat to hold the internal safety magnet open. If the sensor tip is degraded or misaligned, the gas valve shuts off immediately. Inspecting sensor leads and testing or replacing the thermocouple restores proper operation across direct-vent systems and multi-sided linear gas fireplaces.
How long are the replacement lead wires on Heatilator propane pilot assemblies?
Replacement pilot assemblies usually feature wire leads and gas tubing measuring between 24 and 36 inches. For instance, the 4021-737 pilot assembly provides a 36-inch thermopile with 24-inch thermocouple, ignitor wire, and pilot tubing. Measuring your existing line run from the burner bracket to the gas valve before ordering ensures clean routing without sharp tube bends that restrict gas flow.
How do I verify if the 060-523 variable propane gas valve fits my fireplace?
Verify compatibility by matching the serial tag on your fireplace metal rating plate against the manufacturer compatibility list. The 060-523 variable propane valve replaces millivolt gas valves on select direct-vent units from Heatilator, Heat-N-Glo, and Quadra-Fire. Cross-referencing existing valve part numbers ensures correct electrical resistance, pipe threading, and proper fuel pressure regulation.


Write Your Review
No reviews yet. Be the first to share your experience!